{"product_id":"victron-smartsolar-mppt-150-35-scc115035210","title":"Victron - SmartSolar MPPT 150\/35 Solar Charge Controller (150V max PV, 35A, Bluetooth) - SCC115035210","description":"\u003cp\u003e\u003cstrong\u003eThe Victron SmartSolar MPPT 150\/35 is a 35A maximum power point tracking solar charge controller for 12V, 24V and 48V systems, with a 150V PV input ceiling that lets you wire panels in series.\u003c\/strong\u003e It tracks the array's maximum power point continuously, converts the surplus voltage into charge current, and runs a multi-stage adaptive charge algorithm you can override entirely. Peak efficiency is 98 percent. Bluetooth is built in, so it sets up from VictronConnect on your phone.\u003c\/p\u003e\n\n\u003cp\u003eThis is the model you step up to when the array outgrows the 100V family or when the wiring makes more sense in series. Big canopy and roof arrays, expedition vehicles, cabins, sheds and small off-grid installations. It handles 48V systems, which none of the 100V models in this range do.\u003c\/p\u003e\n\n\u003ch3\u003eCritical: there is no physical load output on this model\u003c\/h3\u003e\n\n\u003cp\u003eRead this before you buy, because it is the thing buyers are most annoyed to discover afterwards.\u003c\/p\u003e\n\n\u003cp\u003eThe 150\/35 has a \u003cstrong\u003evirtual\u003c\/strong\u003e load output only. There are no load terminals. You cannot wire lights or a fridge to the controller and have it power them. What the virtual load output actually does is switch an external relay - the controller decides when the load should be dropped and signals accordingly, and the relay does the switching.\u003c\/p\u003e\n\n\u003cp\u003eTo use it at all you need a \u003cstrong\u003eVE.Direct TX cable, sold separately\u003c\/strong\u003e, plus a suitable relay. That is the whole picture, and it is the same arrangement on the 100\/30 and 100\/50. If you want load terminals you can wire straight into, you want a smaller controller - the 75\/10 or 75\/15 have real load outputs rated at 15A continuous.\u003c\/p\u003e\n\n\u003cp\u003eFor most builds at this size this is a non-issue, because a system big enough to justify a 150\/35 usually has proper distribution and low voltage protection downstream anyway. But go in knowing it.\u003c\/p\u003e\n\n\u003ch3\u003eHow much solar can you run on a 150\/35?\u003c\/h3\u003e\n\n\u003cp\u003eTwo numbers govern it, and on this model the voltage number is the reason to buy it.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePanel wattage:\u003c\/strong\u003e 500W at 12V, 1000W at 24V, or 2000W at 48V. That is the nominal PV power the controller converts. Note how sharply the usable array grows with battery voltage - if you are anywhere near the top of the 12V figure, a 24V or 48V bank makes far better use of the same controller.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eArray open circuit voltage:\u003c\/strong\u003e maximum PV open circuit voltage is 150V, and maximum PV short circuit current is 40A. The 150V ceiling is the point of this model. It gives you room to wire panels in series, which raises string voltage and lets you run smaller cable over a long roof-to-battery run with less voltage drop. Series is also what gets a large array within the controller's current limit.\u003c\/p\u003e\n\n\u003cp\u003eThe catch with series is cold weather. Open circuit voltage climbs as panel temperature falls, so a string that reads comfortably under 150V in summer can exceed it on a cold morning - and exceeding it is how controllers die. Take the Voc figure printed on the panel label, multiply by the number of panels in the string, and leave real headroom for the coldest morning the vehicle or building will ever see. If the sum is close, drop a panel out of the string.\u003c\/p\u003e\n\n\u003ch3\u003eThe bit no one explains: VE.Smart Networking\u003c\/h3\u003e\n\n\u003cp\u003eA Smart Battery Sense, SmartShunt or BMV-712 measures voltage and temperature at the battery terminals and broadcasts them over Bluetooth. The 150\/35 listens and sets its charge voltage from that reading rather than from its own terminals.\u003c\/p\u003e\n\n\u003cp\u003eIt matters more the bigger the system gets. The controller sits at the end of a cable, and at 35A that cable drops real voltage. The controller reads high, decides the battery is fuller than it is, and tapers early - every cycle. Feed it a true battery-side reading and the bank actually reaches full.\u003c\/p\u003e\n\n\u003cp\u003eSynchronised charging is supported too. Run more than one SmartSolar MPPT - a roof array on one and a second array or a portable on another, which is common at this size - and over the same VE.Smart network they move through bulk, absorption and float together instead of each running its own private program. A network takes up to 10 devices, but only one sense source is allowed. One sensor, many chargers.\u003c\/p\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150V maximum PV open circuit voltage\u003c\/strong\u003e - room to wire panels in series and run smaller cable over a long roof run\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e35A maximum charge current\u003c\/strong\u003e across 12V, 24V and 48V systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra fast maximum power point tracking\u003c\/strong\u003e - noticeably better in changeable cloud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak efficiency of 98 percent\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-stage adaptive charge algorithm\u003c\/strong\u003e, or fully user defined if your battery has its own numbers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEqualisation is disabled by default\u003c\/strong\u003e - there for flooded lead acid, off unless you enable it\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBluetooth built in\u003c\/strong\u003e - configure, monitor and update firmware from VictronConnect\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVE.Direct port\u003c\/strong\u003e for a wired connection to a GX device or a PC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVE.Smart Networking\u003c\/strong\u003e - battery-side voltage and temperature sense, plus synchronised charging with other SmartSolar controllers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVery low self consumption\u003c\/strong\u003e - 20mA at 12V, 15mA at 24V, 10mA at 48V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVirtual load output\u003c\/strong\u003e - switches an external relay, and needs a VE.Direct TX cable, sold separately\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16mm2 (AWG6) power terminals\u003c\/strong\u003e - sized for the current this thing actually moves\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eMounting it - read this before you pick a spot\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eThis is an indoor unit.\u003c\/strong\u003e Protection category is IP43 for the electronics and IP22 for the connection area. It is not sealed and it is not waterproof. Do not mount it in an engine bay, under a tray, in a wheel arch, or anywhere exposed to rain, road spray or dust. A dry, ventilated interior space is what it is designed for.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount it vertically, terminals facing downwards.\u003c\/strong\u003e Not flat, not on its side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount it on a non-flammable substrate.\u003c\/strong\u003e At 35A the heatsink gets hot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeave clear air above and below the unit.\u003c\/strong\u003e This one relies on convection more than the small models do - box it in and you will lose output on hot days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount it within 3 metres of the battery, but never directly above it.\u003c\/strong\u003e Close, for voltage drop. Not above, because batteries vent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not mount it in a user-accessible area.\u003c\/strong\u003e Live terminals at meaningful current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower terminals accept 16mm2 (AWG6) cable.\u003c\/strong\u003e Size the run for length and current, not just to fill the lug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery supply fuse: minimum 40A, maximum 45A.\u003c\/strong\u003e Fit it on the battery positive, as close to the battery as practical. This is not optional.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck battery polarity twice.\u003c\/strong\u003e Reverse battery polarity blows an internal fuse that is not practically user-replaceable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe WireBox-M terminal cover fits this model\u003c\/strong\u003e if you want the connection area shrouded. Sold separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eConnect the battery first, then the PV. Disconnect in the reverse order. Full rated output is only available up to 40C ambient and up to 2000m altitude - above either, the controller derates itself to protect the electronics.\u003c\/p\u003e\n\n\u003ch3\u003eFull specifications\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSKU: \u003cstrong\u003eSCC115035210\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eBattery voltage: \u003cstrong\u003e12V, 24V or 48V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum battery charge current: \u003cstrong\u003e35A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal PV power at 12V: \u003cstrong\u003e500W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal PV power at 24V: \u003cstrong\u003e1000W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal PV power at 48V: \u003cstrong\u003e2000W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum PV open circuit voltage: \u003cstrong\u003e150V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum PV short circuit current: \u003cstrong\u003e40A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePeak efficiency: \u003cstrong\u003e98 percent\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSelf consumption at 12V: \u003cstrong\u003e20mA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSelf consumption at 24V: \u003cstrong\u003e15mA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSelf consumption at 48V: \u003cstrong\u003e10mA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLoad output: \u003cstrong\u003evirtual only, no load terminals, requires a VE.Direct TX cable sold separately\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCharge algorithm: \u003cstrong\u003emulti-stage adaptive, or user defined\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEqualisation: \u003cstrong\u003edisabled by default\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eBattery supply fuse: \u003cstrong\u003e40A minimum, 45A maximum\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eData communication: \u003cstrong\u003eVE.Direct port and Bluetooth\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOperating temperature: \u003cstrong\u003e-30C to +60C, full rated output up to 40C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum altitude: \u003cstrong\u003e5000m, full rated output up to 2000m\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProtection category: \u003cstrong\u003eIP43 electronics, IP22 connection area\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower terminals: \u003cstrong\u003e16mm2 \/ AWG6\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDimensions: \u003cstrong\u003e130 x 186 x 70 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eWeight: \u003cstrong\u003e1.25 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eColour: \u003cstrong\u003eblue, RAL 5012\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eWarranty: \u003cstrong\u003e5 years\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eDoes the 150\/35 have a load output I can wire a fridge to?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003e\u003cp\u003eNo. There are no load terminals on this model. It has a virtual load output, which switches an external relay rather than powering anything through the controller. To use it you need a VE.Direct TX cable, sold separately, and a suitable relay. If you want real load terminals, the SmartSolar 75\/10 and 75\/15 have a physical load output rated at 15A continuous.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eHow much solar can I run on a 150\/35?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003e\u003cp\u003e500W at 12V, 1000W at 24V, or 2000W at 48V. The higher your battery voltage, the more array the same controller will handle. The other limit is array open circuit voltage, which must stay under 150V.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eCan I wire my panels in series?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003e\u003cp\u003eYes, and that is the main reason to choose this model. The 150V PV input ceiling gives you room to put panels in series, which raises string voltage and cuts voltage drop over a long cable run. Watch the cold weather though - open circuit voltage rises as panels get cold. Take the Voc figure from the panel label, multiply by the number of panels in the string, and leave headroom for the coldest morning the system will see. Exceeding 150V will destroy the controller.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eWhat fuse do I need on the battery side?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003e\u003cp\u003eMinimum 40A, maximum 45A, fitted on the battery positive as close to the battery as practical. The power terminals take 16mm2 (AWG6) cable, and the run should be sized for its length and current, not just to fill the terminal.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eIs it weatherproof? Can it go in an engine bay?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003e\u003cp\u003eNo. Protection category is IP43 for the electronics and IP22 for the connection area. That is an indoor rating. It must not be mounted in an engine bay or anywhere exposed to rain, road spray or dust. Mount it vertically with the terminals facing downwards, on a non-flammable substrate, with clear air above and below.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eWill it run a 48V battery bank?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003e\u003cp\u003eYes. The 150\/35 supports 12V, 24V and 48V, and at 48V it will handle up to 2000W of panel. The charge algorithm is multi-stage adaptive or fully user defined, so lithium banks with specific voltage requirements are straightforward. Equalisation is disabled by default, which is what you want on lithium.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eThe panels are in the sun but the controller shows nothing. Is it faulty?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003e\u003cp\u003eProbably not. PV voltage has to exceed battery voltage plus 5V for the controller to start, then stay above battery voltage plus 1V to keep running. In weak light the array never gets there, so the controller sits idle and reports nothing. That is normal, not a fault.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eShipping and support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDispatched from our \u003cstrong\u003eQueensland\u003c\/strong\u003e warehouse, with tracking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine Victron stock\u003c\/strong\u003e, backed by the full \u003cstrong\u003e5 year warranty\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAustralian owned and operated. Questions before you buy? Call us on \u003cstrong\u003e07 5211 0841\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eIf your array fits under 100V, the \u003ca href=\"\/products\/victron-smartsolar-mppt-100-15-bluetooth-scc110015060r\"\u003eSmartSolar MPPT 100\/15\u003c\/a\u003e, \u003ca href=\"\/products\/victron-100-20-mppt-smartsolar\"\u003e100\/20\u003c\/a\u003e, \u003ca href=\"\/products\/victron-smartsolar-mppt-100-30-solar-charge-controller\"\u003e100\/30\u003c\/a\u003e and \u003ca href=\"\/products\/victron-smartsolar-mppt-100-50-scc110050210\"\u003e100\/50\u003c\/a\u003e cover 12V and 24V systems, and the 100\/50 carries more charge current than this model. For more current at 150V, see the \u003ca href=\"\/products\/victron-smartsolar-mppt-150-45\"\u003eSmartSolar MPPT 150\/45\u003c\/a\u003e and \u003ca href=\"\/products\/victron-smartsolar-mppt-150-60-tr-scc115060211\"\u003e150\/60-Tr\u003c\/a\u003e. For a small build that needs real load terminals, look at the SmartSolar 75\/10 or 75\/15. The full range is in our \u003ca href=\"\/collections\/victron\"\u003eVictron collection\u003c\/a\u003e.\u003c\/p\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":46567015055556,"sku":"SCC115035210","price":232.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2517\/4562\/files\/SmartSolarMPPT150-35-02685.jpg?v=1792101137","url":"https:\/\/www.raingersupplyco.com.au\/products\/victron-smartsolar-mppt-150-35-scc115035210","provider":"Rainger Supply Co","version":"1.0","type":"link"}