The Victron Busbar is a high current DC distribution point: one common connection for your batteries and DC equipment instead of a stack of ring terminals fighting for space on a battery post. Three variants cover most 12V and 24V builds - 150A with four posts, 150A with six posts, and 250A with four posts. Every model ships with a protective cover, and the bar is tin-plated copper on all three.
Positives to one bar, negatives to another, one heavy cable back to each battery terminal. It is not a fused distribution block and it does not protect anything - it joins conductors. Overcurrent protection stays at the source.
Which busbar do I need?
-
What is the maximum current that will actually flow through the bar? Not the sum of every fuse in the van - the real peak through that one bar. Size to it, then pick 150A or 250A.
-
How many connections do you need, including the ones you have not thought of yet? People count today's cables, buy the four post, then add a solar controller later and end up double-stacking lugs. If you are near the limit, take the 150A six post.
Stud sizes are imperial
-
150A models: 1/4 inch stud (6.35 mm)
-
250A model: 5/16 inch stud (8 mm)
Pick ring lugs to suit the stud size above, and use the supplied nuts.
Key features
-
Tin-plated copper bar, cross section sized to the current rating
-
Protective cover included with every model
- 70 VDC maximum
-
Choice of post count at 150A - four or six posts, same stud and materials
-
Flame-retardant base - ABS to UL 94 V-0
Mounting it
-
Torque differs by model: 150A models 7 Nm, 250A model 13 Nm. Under-torqued joints do not fail loudly, they heat up. Use a torque wrench.
-
Cover access: the 150A models have a clear polycarbonate cover so you can inspect the terminals without touching them. The 250A cover is opaque ABS and has to come off to look.
-
Cable size: Victron specify stud size and current rating, not a maximum cable cross-section. Size cable to the current and run length, then pick a lug to suit the stud.
-
Voltage ceiling: 70 VDC maximum - check your peak charge voltage, not nominal.
Full specifications
All models: maximum voltage 70 VDC, bar tin-plated copper, base ABS, UL 94 V-0, cover included, Victron warranty 5 years.
150A 4 post:
- Stud: 1/4 inch (6.35 mm)
- Torque: 7 Nm
- Bar section: 1.4 x 18 mm
- Dimensions with cover: 45 x 152.4 x 31.8 mm
- Weight: 0.2 kg
- Cover: clear polycarbonate, UL 94 HB
- SKU: VBB115040020
150A 6 post:
- Stud: 1/4 inch (6.35 mm)
- Torque: 7 Nm
- Bar section: 1.4 x 18 mm
- Dimensions with cover: 45 x 231.7 x 31.8 mm
- Weight: 0.27 kg
- Cover: clear polycarbonate, UL 94 HB
- SKU: VBB115060020
250A 4 post:
- Stud: 5/16 inch (8 mm)
- Torque: 13 Nm
- Bar section: 5 x 24 mm
- Dimensions with cover: 48 x 237 x 70 mm
- Weight: 0.24 kg
- Cover: opaque ABS, UL 94 V-2
- SKU: VBB125040010
Frequently Asked Questions
What size are the studs?
Imperial sizes. 1/4 inch (6.35 mm) on the 150A models and 5/16 inch (8 mm) on the 250A.
Which ring lugs do I need?
Pick a lug to suit the stud size for your model and size the cable to your current and run length. Use the supplied nuts.
Should I get the 150A four post or the six post?
Same rating and materials - you are choosing how many connections you can land. Count today's cables plus the ones you will add, and take the six post if it is close.
What torque should I use?
7 Nm on the 150A models and 13 Nm on the 250A.
Shipping and support
- Dispatched from our Queensland warehouse, with tracking
-
Genuine Victron stock, backed by Victron's 5 year warranty
- Australian owned and operated. Questions before you buy? Message us