Victron - SmartSolar MPPT 150/45 Solar Charge Controller (150V max PV, 45A, Bluetooth)
SCC115045212
- Shipping Available
- Low stock - order soon
- Open for backorder - secure yours
Product Description
The Victron SmartSolar MPPT 150/45 is a 45A maximum power point tracking solar charge controller for 12V, 24V and 48V systems, with a 150V PV input ceiling that lets you wire panels in series. It tracks the array's maximum power point continuously, converts surplus panel voltage into charge current, and runs a multi-stage adaptive charge algorithm - eight pre-programmed settings on a rotary switch, or fully user defined. Peak efficiency is 98 percent with no cooling fan. Bluetooth is built in, so it sets up and monitors from VictronConnect on your phone.
It shares its case with the SmartSolar 150/35 and carries 10A more charge current. This is the controller for big canopy and roof arrays, expedition vehicles, caravans with a 24V or 48V bank, cabins and sheds - anywhere the array has outgrown the 100V family or the wiring makes more sense in series.
How much solar can you run on a 150/45?
Panel wattage: 650W at 12V, 1300W at 24V, 1950W at 36V or 2600W at 48V. That is the nominal PV power the controller converts. If more panel is connected, the controller simply limits input power. Note how sharply the usable array grows with battery voltage - near the top of the 12V figure, a 24V or 48V bank makes far better use of the same controller.
Array voltage and current: maximum PV open circuit voltage is 150V absolute maximum in the coldest conditions, with 145V as the start-up and operating maximum. Maximum PV short circuit current is 50A. The 150V ceiling gives you room to wire panels in series, which raises string voltage and lets you run smaller cable over a long roof-to-battery run with less voltage drop.
The catch with series is cold weather. Open circuit voltage climbs as panel temperature falls, so a string that sits comfortably under the limit in summer can exceed it on a cold morning - and exceeding it is how controllers die. Take the Voc printed on the panel label, multiply by the number of panels in the string, and leave real headroom for the coldest morning the system will see.
The PV voltage must exceed battery voltage plus 5V for the controller to start, and then stay above battery voltage plus 1V to keep running.
Battery-side sensing over Bluetooth
A Smart Battery Sense or a BMV-712 Smart Battery Monitor can send true battery voltage and temperature to the 150/45 over Bluetooth. At 45A the cable between controller and battery drops real voltage, so a battery-side reading means the controller charges to what the battery actually needs instead of what it sees at its own terminals.
Key features
- 150V maximum PV open circuit voltage - room to wire panels in series
- 45A rated charge current across 12V, 24V and 48V systems (36V selectable with the software tool)
- Ultra fast maximum power point tracking - Victron quote up to 30 percent more harvest than PWM and up to 10 percent more than slower MPPT controllers in changing cloud
- Partial shading MPP detection - locks to the optimum power point when shading creates more than one
- 98 percent maximum efficiency, no cooling fan
- Eight pre-programmed charge algorithms on a rotary switch, or a fully programmable algorithm
- Protection - over-temperature with power derating, PV short circuit, PV reverse polarity and PV reverse current
- Internal temperature sensor compensates absorption and float voltage
- Fully discharged battery recovery - will start charging a battery discharged to zero volts, and reconnect to a lithium battery that has disconnected itself
- Bluetooth and VE.Direct - phone app set-up and monitoring, plus a wired port for a GX device or PC
- 46 days of stored trends - battery voltage, current and temperature, PV voltage and PV current
- Battery and PV terminals only - there are no load output terminals on this model
Mounting it
This is an indoor unit. Protection category is IP43 for the electronics and IP22 for the connection area. Do not mount it in an engine bay, under a tray or anywhere exposed to rain, road spray or dust. Operating temperature is -30C to +60C, with full rated output up to 40C. Power terminals take 16mm2 (AWG6) cable. Follow the Victron manual for cable sizing and battery fusing. The WireBox-M terminal cover fits this case if you want the connection area shrouded, sold separately.
Full specifications
- Battery voltage: 12V, 24V or 48V auto select (36V with software tool)
- Rated charge current: 45A
- Nominal PV power: 650W at 12V, 1300W at 24V, 1950W at 36V, 2600W at 48V
- Maximum PV short circuit current: 50A
- Maximum PV open circuit voltage: 150V absolute maximum coldest conditions, 145V start-up and operating maximum
- Maximum efficiency: 98 percent
- Self consumption: 20mA at 12V, 15mA at 24V, 10mA at 48V
- Charge voltage absorption (default): 14.4 / 28.8 / 43.2 / 57.6V, adjustable
- Charge voltage float (default): 13.8 / 27.6 / 41.4 / 55.2V, adjustable
- Temperature compensation: -16mV / -32mV / -64mV per C
- Data communication: VE.Direct port and Bluetooth
- Operating temperature: -30C to +60C, full rated output up to 40C
- Humidity: 95 percent, non-condensing
- Protection category: IP43 electronics, IP22 connection area
- Power terminals: 16mm2 / AWG6
- Dimensions (h x w x d): 130 x 186 x 70 mm
- Weight: 1.25 kg
- Colour: blue, RAL 5012
- Safety: EN/IEC 62109-1, UL 1741, CSA C22.2
- Warranty: 5 years
Frequently Asked Questions
How much solar can I run on a 150/45?
650W at 12V, 1300W at 24V, 1950W at 36V or 2600W at 48V. The other limit is array open circuit voltage, which must stay under 150V even on the coldest morning.
What is the difference between the 150/35 and the 150/45?
Same case and the same 150V PV limit. The 150/45 carries 45A of charge current against 35A, takes up to 650W of panel at 12V against 500W, and handles 50A of PV short circuit current against 40A.
Does the 150/45 have a load output?
No. It has battery and PV terminals only. If you need load terminals you can wire straight into, the SmartSolar 75/10 and 75/15 have them.
Is it weatherproof?
No. Protection category is IP43 for the electronics and IP22 for the connection area, which is an indoor rating. Mount it somewhere dry and ventilated, away from rain, road spray and dust.
Will it charge a 48V lithium bank?
Yes. It auto selects 12V, 24V or 48V, and at 48V it converts up to 2600W of panel. The charge algorithm can be fully user defined to match your battery maker's numbers.
Shipping and support
- Dispatched from our Queensland warehouse, with tracking
- Genuine Victron stock, backed by the full 5 year warranty
- Australian owned and operated. Questions before you buy? Call us on 07 5211 0841
Smaller arrays under 100V: the SmartSolar MPPT 100/20, 100/30 and 100/50. The full range is in our Victron collection.